Parameter Biometri pada Pasien Katarak Senilis Sebelum Operasi Phacoemulsifikasi dengan Implantasi Lensa Intraokuler di Pekanbaru
Abstract
Senile cataract is an age-related decrease in vision caused by clouding of the lens due to thickening and denaturation of the lens. Phacoemulsification with intraocular lens implantation is one of the most widely used surgical methods worldwide and is very effective in the treatment of cataracts. Keratometry, axial length, anterior chamber depth and central corneal thickness, and lens thickness were measured before phacoemulsification. These measurements are very important to achieve visual quality improvement for the patients. The purpose of this study was to describe of distribution ocular the biometric parameters before phacoemulsification surgery with intraocular lens implantation. This study used a descriptive research method with a cross-sectional design approach with 1032 patients. Axial length, ACD, CCT, LT, K were determined with partial laser interferometry (IOL Master 700). The results of the study showed 55.3% were male, 45,1 % were 61-70 years old, 75,6% were immature senile cataracts, 39.7 % were normal body mass index. The mean and standard deviations K, AL, ACD, CCT, and LT were (44.19±1.49), (23.50±1.21), (3.22±0.42), (522±35.27) and (4.35±0.67). There were statically significant differences when comparing K, AL, and ACD by sex. Axial length, ACD, CCT, and LT were correlated with age. The biometric parameters are influenced by gender, age, and senile cataract stage.
Keywords
Full Text:
PDF (Bahasa Indonesia)References
Puspita R, Ashan H, Sjaaf F. Profil pasien katarak senilis pada usia 40 tahun keatas di RSI Siti Rahmah Tahun 2017. Heal Med J. 2019;1(1):15-21. doi:10.33854/HEME.V1I1.214
Pascolini D, Mariotti SP. Global estimates of visual impairment: 2010. Br J Ophthalmol. 2012;96(5):614-618. doi:10.1136/bjophthalmol-2011-300539
Suriadi N. Analisis polimorfisme gen manganese superoxide dismutase ala-9val dan gen glutathione peroxidase-1 pro18leu pada penderita katarak usia produktif. (Disertasi) Universitas Andalas.2016. Published online 2016.
Yu JG, Zhong J, Mei ZM, Zhao F, Tao N, Xiang Y. Evaluation of biometry and corneal astigmatism in cataract surgery patients from Central China. BMC Ophthalmol. 2017;17(1):1-7. doi:10.1186/s12886-017-0450-2
Fernanda F, Hayati F. Hubungan Usia dan Jenis Kelamin dengan Angka Kejadian Penyakit Katarak di Poli Mata RSUD Meuraxa Banda Aceh. Universitas Abulyatama Jurnal Aceh Medika. 2020;9623:36-42.
Gracella FL, Sutyawan IWE, Triningrat AAMP. Karakteristik penderita katarak senilis di Rumah Sakit Umum Pusat Sanglah Tahun 2014. E-Jurnal Med. 2017;6(12):151-156.
Natung T, Shullai W, Nongrum B, Thangkhiew L, Baruah P, Phiamphu ML. Ocular biometry characteristics and corneal astigmatisms in cataract surgery candidates at a tertiary care center in North-East India. Indian J Ophthalmol. 2019;67(9):1417-1423. doi:10.4103/ijo.IJO_1353_18
Hoffmann PC, Hütz WW. Analysis of biometry and prevalence data for corneal astigmatism in 23 239 eyes. J Cataract Refract Surg. 2010;36(9):1479-1485. doi:10.1016/j.jcrs.2010.02.025
Cui Y, Meng Q, Guo H, et al. Biometry and corneal astigmatism in cataract surgery candidates from Southern China. J Cataract Refract Surg. 2014;40(10):1661-1669. doi:10.1016/j.jcrs.2014.01.039
Wong TY, Foster PJ, Johnson GJ, Klein BEK, Seah SKL. The relationship between ocular dimensions and refraction with adult stature: The Tanjong Pagar survey. Investig Ophthalmol Vis Sci. 2001;42(6):1237-1242.
Yu JG, Zhong J, Mei ZM, Zhao F, Tao N, Xiang Y. Evaluation of biometry and corneal astigmatism in cataract surgery patients from Central China. BMC Ophthalmol. 2017;17(1):2-8. doi:10.1186/s12886-017-0450-2
Meng W, Butterworth J, Malecaze F, Calvas P. Axial length of myopia: A review of current research. Ophthalmologica. 2011;225(3):127-134. doi:10.1159/000317072
Huang Q, Huang Y, Luo Q, Fan W. Ocular biometric characteristics of cataract patients in western China. BMC Ophthalmol. 2018;18(1):1-9. doi:10.1186/s12886-018-0770-x
Hashemi H, Yekta A, Shokrollahzadeh F. The distribution of keratometry in a population based study. J Curr Ophthalmol. 2021;33(1):17-22. doi:10.1016/j.joco.2019.06.004
Shufelt C, Fraser-Bell S, Ying-Lai M, Torres M, Varma R. Refractive error, ocular biometry, and lens opalescence in an adult population: The Los Angeles Latino Eye Study. Investig Ophthalmol Vis Sci. 2005;46(12):4450-4460. doi:10.1167/iovs.05-0435